•0.01mA resolution for DC current
•Top class measurement 0.2% accuracy
•Φ6mm clamp jaw easy to use in tight places
•Measurement from 0.01mA to 120.0mA
•Dual display with backlight shows both mA measurement and percent of 4-20 mA span
•Spotlight for illuminating measurement point
•Analog output terminal for recorder connection
•Complies with IEC 61010-1 CAT.II 300V

AC Digital Clamp Meters

MODEL2002PA
Selection GuideProduct CatalogueInstruction Manual


•Can measure large AC current up to 2000A.
•Peak hold function.
•55mm-dia large tear drop shaped jaws.

MODEL2002R
Selection GuideInstruction Manual


•Can measure large AC current up to 2000A.
•Peak hold function.
•55mm-dia large tear drop shaped jaws.

MODEL2006
Selection GuideInstruction Manual


•Pocket size, handy clamp meter.
•UL listed fire retardant plastic housing case.
•Multifunction instrument having voltage and resistance measurement functions in addition to all the ranges incorporated.

2007A
Selection GuideProduct CatalogueInstruction Manual


•Sleep function to save battery
•Data hold function.
•Digital display with maximum 4000 counts.

2017
Selection GuideInstruction Manual

•Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
•Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
•Three functions in one unit; AC current, AC voltage and resistance.
•Resistance range provides audible continuity test.
•Frequency response from 40Hz to 1kHz on AC current and voltage ranges.

MODEL2027
Selection GuideInstruction Manual

•True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
•Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
•Three functions in one unit; AC current, AC voltage and resistance.

MODEL2031
Selection GuideProduct CatalogueInstruction Manual


•Can measure large AC current up to 200A.
•24mm-dia tear drop shaped jaws.

KEW2040

•Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
•CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
•Thus, very useful for power distribution companies, power utilities and maintenance fields.

KEW2200

The Slim and Lightweight 1000A AC Clamp Meter


AC Analogue Clamp Meters

MODEL2608A



•DC voltage range is also available especially for checking emergency battery operated power supply.
•Can measure temperature using optional probe.
•Tear drop shaped transformer jaws for ease of use.

2805
Selection Guide


•Range switch selects only one rotary scale at a time, making it easy to take readings correctly.
•A long time seller with proven reputation world wide for its easy-to-use functions.


2003A



l

•Equipped to measure both AC and DC current with transformer jaws of large diameter.
•Can measure AC and DC currents up to 2000A.
•Output terminal for connection to recorders.

MODEL2004


l

•Smallest clamp meter capable of AC and DC current measurements.
•20A range has a minimum resolution of 0.01A AC/DC.
•AC/DC voltage and resistance measurement functions also available.

KEW2009R


•CAT.IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
•Accurate True-RMS reading of AC current or voltage with distorted waveform.
•Can measure AC and DC currents up to 2000A.
•Output terminal for connection to recorders.

MODEL2010



•High sensitivity, miniature AC/DC clamp meter.
•0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
•Output terminal for recorder connection.

MODEL2033


•Smallest clamp meter capable of AC and DC current measurements.
•300A auto ranging has minimum resolution of 0.01A AC/DC.
•Auto-zero function to allow one touch zero adjustment.

2046R


•Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
•CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
•Thus, very useful for power distribution companies, power utilities and maintenance fields.
•True RMS enables an accurate measurement.

KEW2055

•Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
•CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
•Thus, very useful for power distribution companies, power utilities and maintenance fields.

KEW2056R

•Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
•CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
•Thus, very useful for power distribution companies, power utilities and maintenance fields.
•True RMS enables an accurate measurement.

Fork Current Tester

MODEL2300R

•True RMS reading is an essential feature for accurate measurement.
•“Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
•Set the DC current range to zero in one touch with the Zero Adjust function.

Leakage Clamp Meters

MODEL2412

•Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
•Frequency filter switch to eliminate the effect of harmonics.
•Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.

KEW2413F

•Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
•Frequency filter switch to eliminate the effect of harmonics.
•Output terminal.

2413R
Leakage Clamp Meter






•Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
•True RMS enables an accurate measurement for distorted waveforms.
•Measurement from mA up to AC 1000A
•Frequency filter switch to eliminate the effect of the harmonics.
•2 way analogue output terminal

2431



l


•Frequency Selector Switch to eliminate the effect of harmonics.
•Three AC current ranges 20mA/200mA/200A.
•Rotary switch for easy one finger power-on and range selection.

MODEL2432



•High Sensitive Model
•Frequency Selector Switch to eliminate the effect of harmonics.
•Three AC current ranges:4mA/40mA/100A

2433



•Frequency Selector Switch to eliminate the effect of harmonics.
•Three AC current ranges:40mA/400mA/400A.

MODEL2433R


•Frequency Selector Switch to eliminate the effect of harmonics.
•Three AC current ranges:40mA/400mA/400A.


MODEL2434


•Least affected by external stray magnetic field.
•20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
•Frequency Selector Switch to eliminate the effect of harmonics.